Patient 1:
A 45-year-old male presented to the emergency department with complaints of chest pain for the past 7 hours. He had no risk factors and had no co-morbidities.
His first ECG is shown below.
The above ECG showed Normal sinus rhythm with a heart rate of 75 beats per minute. The ECG also showed deep Q waves in lead III and a small Q wave in lead aVF with a concave upward ST segment. The ECG also showed hyperacute T waves in Lead V2 and a positive T wave in Lead V1. The presumed Hyperacute T wave and the positive T wave can be an evolved/previous ECG change of the posterior wall ischemia, which can be evident by flipping the ECG shown below.
The Tall R wave in V2 represents the Q wave of the posterior wall (Blue arrow), and hyperacute T waves represent the inverted T wave (Brown arrow)
As the patient had typical chest pain, a serial ECG and cardiac biomarkers were planned. An ECG was repeated after 45 minutes, as shown below.
The above ECG showed Normal sinus rhythm at a rate of 75 beats per minute with minimal ST depression in lead III and a concave upward ST segment elevation in lead aVL. These changes were presumed to be new and were considered dynamic changes.
However, after careful examination of the ECG and comparing it with the previous ECG, these changes were found to be due to lead reversal.
Here, the left arm and the left foot leads were reversed, resulting in the supposed dynamic ECG changes. As explained in the image below, when LA and LF leads are reversed, the entire ECG complexes (P, QRS & T) will get flipped vertically.
In a patient with normal ECG in lead III, this will often result in deep Q waves, which can be mistaken for ischemia.
Similarly, when the Left arm and left foot are reversed, aVL will record aVF, and aVF will record aVL.
Hence, these two ECG waveforms should be switched around, as shown below.
Deep dive into lead reversal:
In order to understand limb lead reversals, we need to understand Einthoven's triangle.
Lead I is obtained by placing the negative pole in RA and the positive pole in LA
Lead II is obtained by placing the negative pole in RA and the positive pole in LF
Lead III is obtained by placing the negative pole in LA and the positive pole in the LF
For augmented leads, aVR, aVL & aVF, the negative pole is an imaginary pole (centre of the heart), and the positive pole is placed in RA, LA & LF, respectively.
Of course, all these are achieved by just placing the 4 lead clips on the patient in the limbs, The red clip in the right arm, the yellow clip in the left arm, the green clip in the left foot and the black clip, which is the neutral pole in the right foot.
The ECG machine then alternates the polarity between positive and negative in the left arm clip to record the respective leads.
Modern ECG machines don't exactly record the ECGs. They only record lead I and derive lead II, III, aVL, aVF, and aVR based on Einthoven's equation.
Hence, when we interchange the leads, we will record wrong ECG complexes that can potentially mimic pathologies.
RA and LA reversal:
This is the most common lead reversal encountered in clinical settings.
When the RA clip is kept in the left arm and the LA clip is kept in the right arm, the following changes happen as depicted in the picture. (The left picture is normal & Right picture shows RA & LA reversed)
Lead I becomes inverted (Red arrow)
Leads II and III switch places (Purple and green arrow)
Leads aVL and aVR switch places (Peacock and black arrow)
Lead aVF remains unchanged (Yellow arrow)
How will it look like in a 12-lead ECG?:
- Lead I will be completely inverted (P wave, QRS complex and T wave)
- Lead aVR will, most of the time, completely become positive (P wave, QRS complex and T wave)
- There may be marked right-axis deviation
RA/LA reversal most often mimics Dextrocardia; however, in Dextrocardia, there will be a reverse progression of R wave in the chest leads, i.e. QRS in V1 will be positive and in V6 will be negative.
The above ECG shows a predominantly negative P, QRS and T wave in Lead I and a predominantly positive P, QRS, and T wave in Lead aVR with the preserved progression of QRS in the chest leads.
The above ECG shows a predominantly negative P, QRS and T wave in Lead I and a predominantly positive P, QRS, and T wave in Lead aVR with the reverse progression of QRS in the chest leads with positive QRS in V1 and negative QRS in V6.
LA and LF reversal:
When the LA clip is kept on the left foot and the LF clip is kept on the left arm, the following changes happen as depicted in the picture. (The left picture is normal & Right picture shows LA & LF reversed)

- Lead III becomes inverted (Purple arrow)
- Leads I and II switch places (Green arrow and Red arrow)
- Leads aVL and aVF switch places (Yellow and peacock colour arrow)
- Lead aVR remains unchanged (Black arrow)
How will it look like in a 12-lead ECG?:
- The P-wave is unexpectedly larger in lead I than lead II (it is usually the other way around)
Observe that the P wave in lead I is taller than the P wave in lead II.
RA & LL reversal:
When the RA clip is kept in the left foot, and the LF clip is kept in the right arm, the following changes happen as depicted in the picture. (The left picture is normal & Right picture shows RA & LL reversed)
- Lead II becomes inverted (Green arrow)
- Leads I and III become inverted and switch places (Red and purple arrow)
- Leads aVR and aVF switch places (Black and Yellow arrow)
- Lead aVL is unchanged
How will it look like in a 12-lead ECG?:
- Leads I, II, III and aVF are all completely inverted (P wave, QRS complex and T wave)
- Lead aVR is upright
ECG showing RA, LF reversal. aVR is positive, and Leads I, II, and III are negative.
Algorithmic approach to limb lead reversal
.png)
Check lead aVR first. If the P wave, QRS complex, and T wave are all positive, move to the next step. If not, check the P wave in leads I and II. Normally, the P wave in the lead II should be taller than in the lead I. If the P wave in the lead I is taller than in the lead II, then suspect left arm (LA) and left foot (LF) lead reversal.
If the P, QRS, and T waves are all positive in lead aVR, check their polarity in leads I, II, and III.
- If the P, QRS, and T waves are negative in all three leads (I, II, and III), the right arm (RA) and left foot (LF) leads are reversed.
- If only lead I has negative P, QRS, and T waves, check the R wave progression in the chest leads.
- If R wave progression is normal, RA and LA leads are reversed.
- If R wave progression is reversed, with a tall R wave in V1, suspect dextrocardia.
Comments
Post a Comment